<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-23 02-03-24
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.70 MHz 5/5, 56 dBuV ZUERISEE
Pilot RDS Phase Difference
6.5 kHz 2.3 kHz 86 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 57 kHz 18612 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,3 dBr 2,39 dBr 2,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ZUERISEE" 4F14 10 (Pop M) 1 0 1 1 --:--
RT
-
AF EON
88.4, 106.7 MHz -
FM Scope Max at: 57 kHz MIN: 8 kHz % above 76 kHz: 0,0000 Acquired: 2026.09.23 2.02.21 Total samples: 18612 Equivalent time: 0:15:30 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 2,5 dBr MIN: 2,3 dBr AVE: 2,39 dBr % above 12,2 dBr: 0,0 Last value: 2,4 dBr (2026.09.23 2.02.20) 01.48 01.50 01.52 01.54 01.56 01.58 02.00 02.02 -1 0 1 2 3 Pm [dBr]