<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-23 01-27-28
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.20 MHz 5/5, 62 dBuV R1 GANCE
Pilot RDS Phase Difference
6.2 kHz 5.1 kHz 90 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 9 kHz 13847 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-10,0 dBr -9,69 dBr -9,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R1 GANCE" 2497 15 (Other M) 1 0 1 7 --:--
RT
" "
AF EON
2492, 43B3, F84B, 4F14
FM Scope Max at: 9 kHz MIN: 8 kHz % above 76 kHz: 0,0000 Acquired: 2026.09.23 1.26.25 Total samples: 13847 Equivalent time: 0:11:32 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000 4000
FM Scope MAX: -9,6 dBr MIN: -10,0 dBr AVE: -9,69 dBr % above 12,2 dBr: 0,0 Last value: -9,6 dBr (2026.09.23 1.26.25) 01.12 01.14 01.16 01.18 01.20 01.22 01.24 01.26 -10 -5 0 Pm [dBr]